Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current25A
Release characteristicB
Rated voltage440V
Built-in depth82.5mm
Frequency50 - 60Hz
Voltage typeAC/DC
Pollution degree3
Rated insulation voltage Ui500V
Current limiting class3
Over voltage category4
Width in number of modular spacings4
Power loss17.2W
Number of protected poles4
Degree of protection (IP)IP20
Explosion-proofNo
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Number of poles (total)4
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS884001R0255 | S804C-B25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

25A

Release characteristic

B

Rated voltage

440V

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Voltage type

AC/DC

Pollution degree

3

Rated insulation voltage Ui

500V

Current limiting class

3

Over voltage category

4

Width in number of modular spacings

4

Power loss

17.2W

Number of protected poles

4

Degree of protection (IP)

IP20

Explosion-proof

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Number of poles (total)

4

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.