Aleta.hr
Main Product Image

2CSY1304MC | AUTOMATSKI PREKIDAC, 1P+N, C6 , PR

Code: 1752134

ManufacturerABB
Catalog number2CSY1304MC
EAN code8012542168652

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth56mm
Number of poles (total)2
Rated current6A
Rated insulation voltage Ui2000V
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V1.5kA
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Frequency50 - 60Hz
Number of protected poles1
Flush-mounted installationYes
Release characteristicC
Current limiting class3
Concurrently switching neutral conductorYes
Pollution degree2
Additional equipment possibleYes
Connectable conductor cross section solid-core6 - 6mm²
Connectable conductor cross section multi-wired6 - 6mm²
Ambient temperature during operating-5 - 40°C
Degree of protection (IP)IP20
Over voltage category3
Width in number of modular spacings1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSY1304MC | AUTOMATSKI PREKIDAC, 1P+N, C6 , PR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

56mm

Number of poles (total)

2

Rated current

6A

Rated insulation voltage Ui

2000V

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

1.5kA

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Frequency

50 .. 60Hz

Number of protected poles

1

Flush-mounted installation

Release characteristic

C

Current limiting class

3

Concurrently switching neutral conductor

Pollution degree

2

Additional equipment possible

Connectable conductor cross section solid-core

6 .. 6mm²

Connectable conductor cross section multi-wired

6 .. 6mm²

Ambient temperature during operating

-5 .. 40°C

Degree of protection (IP)

IP20

Over voltage category

3

Width in number of modular spacings

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.