  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Construction size6 modular spacing
Remote signallingNo
Voltage protection level1.3kV
Nominal voltage AC400V
Mounting methodDIN rail (top hat rail) 35 mm
Follow current extinguishing capability-kA
Max. continuous voltage AC440V
Lightning impulse current (10/350 µs)12.5kA
ExhaustingNo
Number of poles3
Max. continuous voltage DC560V
Voltage protection level L-N-kV
Test classType 1 + 2
Nominal voltage DC560V
Signalling at the deviceNone
Max. PV-voltage-V
Degree of protection (IP)IP20
Max. conductor cross section solid (solid, stranded)35mm²
Max. conductor cross section flexible (fine-strand)25mm²
Integrated backup fuseNo
Voltage protection level N-PE-kV
Voltage protection level (DC+/DC- - PE)-kV
Energy-coordinated protection effect with regard to the terminal equipmentNo
Specific energy (W/R)-kJ/Ohm
Voltage protection level (DC+ - DC-)-kV
System configuration TN-CYes
System configuration TN-SYes
System configuration ITYes
System configuration TN-C-SNo
System configuration DCNo
System configuration TTYes
Max. overcurrent protection device, parallel connection (fuse)-A
System configuration TNYes
Voltage protection level L-PE2kV
System configuration otherNo
Max. overcurrent protection device, series connection (fuse)-A
Overcurrent protected voltage tappingNo
Voltage switching spark gap technologyNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815710R4700 | OVR T1-T2 3L 12.5-440s P QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Construction size

6 modular spacing

Remote signalling

Voltage protection level

1.3kV

Nominal voltage AC

400V

Mounting method

DIN rail (top hat rail) 35 mm

Follow current extinguishing capability

-kA

Max. continuous voltage AC

440V

Lightning impulse current (10/350 µs)

12.5kA

Exhausting

Number of poles

3

Max. continuous voltage DC

560V

Voltage protection level L-N

-kV

Test class

Type 1 + 2

Nominal voltage DC

560V

Signalling at the device

None

Max. PV-voltage

-V

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

35mm²

Max. conductor cross section flexible (fine-strand)

25mm²

Integrated backup fuse

Voltage protection level N-PE

-kV

Voltage protection level (DC+/DC- - PE)

-kV

Energy-coordinated protection effect with regard to the terminal equipment

Specific energy (W/R)

-kJ/Ohm

Voltage protection level (DC+ - DC-)

-kV

System configuration TN-C

System configuration TN-S

System configuration IT

System configuration TN-C-S

System configuration DC

System configuration TT

Max. overcurrent protection device, parallel connection (fuse)

-A

System configuration TN

Voltage protection level L-PE

2kV

System configuration other

Max. overcurrent protection device, series connection (fuse)

-A

Overcurrent protected voltage tapping

Voltage switching spark gap technology

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.