Technical specifications

Number of poles4
ExhaustingNo
Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level L-N1.3kV
Lightning impulse current (10/350 µs)12.5kA
Max. continuous voltage AC440V
Max. continuous voltage DC-V
Nominal voltage AC400V
Voltage protection level0.8kV
Construction size8 modular spacing
Remote signallingNo
Test classType 1 + 2
Nominal voltage DC-V
Signalling at the deviceNone
Follow current extinguishing capability-kA
Voltage protection level N-PE1.3kV
System configuration TN-CNo
Max. conductor cross section solid (solid, stranded)35mm²
System configuration DCNo
Specific energy (W/R)-kJ/Ohm
Max. conductor cross section flexible (fine-strand)25mm²
Voltage protection level (DC+ - DC-)-kV
Max. overcurrent protection device, parallel connection (fuse)-A
Max. PV-voltage-V
Energy-coordinated protection effect with regard to the terminal equipmentNo
System configuration TN-C-SNo
System configuration ITNo
System configuration TN-SYes
System configuration otherNo
Integrated backup fuseNo
System configuration TNNo
Voltage protection level L-PE1.9kV
System configuration TTYes
Overcurrent protected voltage tappingNo
Max. overcurrent protection device, series connection (fuse)-A
Voltage switching spark gap technologyNo
Degree of protection (IP)IP20
Voltage protection level (DC+/DC- - PE)-kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB815710R4800 | OVR T1-T2 3N 12.5-440s P QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Exhausting

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level L-N

1.3kV

Lightning impulse current (10/350 µs)

12.5kA

Max. continuous voltage AC

440V

Max. continuous voltage DC

-V

Nominal voltage AC

400V

Voltage protection level

0.8kV

Construction size

8 modular spacing

Remote signalling

Test class

Type 1 + 2

Nominal voltage DC

-V

Signalling at the device

None

Follow current extinguishing capability

-kA

Voltage protection level N-PE

1.3kV

System configuration TN-C

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration DC

Specific energy (W/R)

-kJ/Ohm

Max. conductor cross section flexible (fine-strand)

25mm²

Voltage protection level (DC+ - DC-)

-kV

Max. overcurrent protection device, parallel connection (fuse)

-A

Max. PV-voltage

-V

Energy-coordinated protection effect with regard to the terminal equipment

System configuration TN-C-S

System configuration IT

System configuration TN-S

System configuration other

Integrated backup fuse

System configuration TN

Voltage protection level L-PE

1.9kV

System configuration TT

Overcurrent protected voltage tapping

Max. overcurrent protection device, series connection (fuse)

-A

Voltage switching spark gap technology

Degree of protection (IP)

IP20

Voltage protection level (DC+/DC- - PE)

-kV