Suitable for safety functionsYes
Number of protected semiconductor outputs-
Type of interface for safety communicationOther
Protected switch distance ON10mm
Number of contact energized outputs with signalling function0
Number of semiconductor outputs with signalling function1
Mechanical mounting condition for sensorNot flat
Ambient temperature-40 - 80°C
Type of electric connectionConnector M12
Construction type housingSpecial construction
Explosion safety category for gasNone
Explosion safety category for dustNone
Protected switch distance OFF25mm
Number of protected contact energized outputs-
Max. output current at protected output0.05mA
Type of switching outputPNP
Cross-/short circuit identification possibleYes
With monitoring function downstream switching devicesYes
With status indicationYes
Rated supply voltage at AC 50 Hz- - -V
Type of actuationTransponder
SIL according to IEC 615083
Rated supply voltage at DC24 - 24V
Performance level according to EN ISO 13849-1Level e
Rated supply voltage at AC 60 Hz- - -V
Degree of protection (IP)IP67