Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DCNo
System configuration ITNo
System configuration TN-C-SNo
System configuration TN-SNo
System configuration TTNo
Number of conductors (without earthing)-
System configuration otherNo
Max. continuous voltage DC-V
Nominal voltage DC-V
Voltage protection level L-N-kV
Voltage protection level N-PE-kV
Voltage protection level (DC+ - DC-)-kV
Voltage protection level (DC+/DC- - PE)-kV
Follow current extinguishing capability-kA
Specific energy (W/R)-kJ/Ohm
With remote signalling contactNo
Max. conductor cross section flexible (fine-strand)25mm²
ExhaustingNo
Category type 1No
Integrated backup fuseNo
Suitable for outdoor useNo
System configuration TN-CYes
Nominal discharge surge current (8/20)35kA
Nominal voltage AC230V
Lightning impulse current (10/350 µs)25kA
Max. continuous voltage AC255V
Construction size6 modular spacing
System configuration TNYes
Degree of protection (IP)IP20
Max. conductor cross section solid (solid, stranded)35mm²
Signalling at the deviceOptic
Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level1.5kV

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5096981 | MCF75-3+FS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

System configuration IT

System configuration TN-C-S

System configuration TN-S

System configuration TT

Number of conductors (without earthing)

-

System configuration other

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Voltage protection level L-N

-kV

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level (DC+/DC- - PE)

-kV

Follow current extinguishing capability

-kA

Specific energy (W/R)

-kJ/Ohm

With remote signalling contact

Max. conductor cross section flexible (fine-strand)

25mm²

Exhausting

Category type 1

Integrated backup fuse

Suitable for outdoor use

System configuration TN-C

Nominal discharge surge current (8/20)

35kA

Nominal voltage AC

230V

Lightning impulse current (10/350 µs)

25kA

Max. continuous voltage AC

255V

Construction size

6 modular spacing

System configuration TN

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

35mm²

Signalling at the device

Optic

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level

1.5kV