Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Suitable for outdoor useNo
Nominal voltage DC-V
Construction size6 modular spacing
Degree of protection (IP)IP20
Integrated backup fuseNo
Voltage protection level N-PE-kV
Nominal discharge surge current (8/20)35kA
Nominal voltage AC230V
Max. continuous voltage DC-V
Signalling at the deviceOptic
ExhaustingNo
Voltage protection level L-N1.5kV
Voltage protection level (DC+/DC- - PE)-kV
Voltage protection level (DC+ - DC-)-kV
Specific energy (W/R)-kJ/Ohm
System configuration ITNo
System configuration DCNo
System configuration otherNo
System configuration TTYes
System configuration TN-C-SYes
System configuration TN-SYes
System configuration TN-CNo
System configuration TNYes
Lightning impulse current (10/350 µs)100kA
With remote signalling contactYes
Number of conductors (without earthing)4
Voltage protection level1.5kV
Follow current extinguishing capability50kA
Max. continuous voltage AC255V
Category type 1Yes
Max. conductor cross section solid (solid, stranded)35mm²
Max. conductor cross section flexible (fine-strand)35mm²

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5096987 | MCF100-3+NPE+FS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Suitable for outdoor use

Nominal voltage DC

-V

Construction size

6 modular spacing

Degree of protection (IP)

IP20

Integrated backup fuse

Voltage protection level N-PE

-kV

Nominal discharge surge current (8/20)

35kA

Nominal voltage AC

230V

Max. continuous voltage DC

-V

Signalling at the device

Optic

Exhausting

Voltage protection level L-N

1.5kV

Voltage protection level (DC+/DC- - PE)

-kV

Voltage protection level (DC+ - DC-)

-kV

Specific energy (W/R)

-kJ/Ohm

System configuration IT

System configuration DC

System configuration other

System configuration TT

System configuration TN-C-S

System configuration TN-S

System configuration TN-C

System configuration TN

Lightning impulse current (10/350 µs)

100kA

With remote signalling contact

Number of conductors (without earthing)

4

Voltage protection level

1.5kV

Follow current extinguishing capability

50kA

Max. continuous voltage AC

255V

Category type 1

Max. conductor cross section solid (solid, stranded)

35mm²

Max. conductor cross section flexible (fine-strand)

35mm²

From same serie

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.