Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DCNo
System configuration ITNo
System configuration TN-CNo
System configuration otherNo
Number of conductors (without earthing)-
Max. continuous voltage DC-V
Nominal voltage DC-V
Voltage protection level N-PE-kV
Voltage protection level (DC+ - DC-)-kV
Voltage protection level (DC+/DC- - PE)-kV
Specific energy (W/R)-kJ/Ohm
Max. conductor cross section flexible (fine-strand)25mm²
With remote signalling contactNo
ExhaustingNo
Category type 1No
Suitable for outdoor useNo
Integrated backup fuseNo
Lightning impulse current (10/350 µs)25kA
Mounting methodDIN rail (top hat rail) 35 mm
Nominal voltage AC230V
Voltage protection level L-N1.5kV
Max. continuous voltage AC255V
System configuration TTYes
System configuration TNYes
Nominal discharge surge current (8/20)35kA
Follow current extinguishing capability50kA
Signalling at the deviceOptic
Construction size6 modular spacing
Voltage protection level1.5kV
Max. conductor cross section solid (solid, stranded)35mm²
System configuration TN-C-SYes
System configuration TN-SYes
Degree of protection (IP)IP20

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5096987 | MCF100-3+NPE+FS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

System configuration IT

System configuration TN-C

System configuration other

Number of conductors (without earthing)

-

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level (DC+/DC- - PE)

-kV

Specific energy (W/R)

-kJ/Ohm

Max. conductor cross section flexible (fine-strand)

25mm²

With remote signalling contact

Exhausting

Category type 1

Suitable for outdoor use

Integrated backup fuse

Lightning impulse current (10/350 µs)

25kA

Mounting method

DIN rail (top hat rail) 35 mm

Nominal voltage AC

230V

Voltage protection level L-N

1.5kV

Max. continuous voltage AC

255V

System configuration TT

System configuration TN

Nominal discharge surge current (8/20)

35kA

Follow current extinguishing capability

50kA

Signalling at the device

Optic

Construction size

6 modular spacing

Voltage protection level

1.5kV

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN-C-S

System configuration TN-S

Degree of protection (IP)

IP20