Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Nominal discharge surge current (8/20)5kA
Category type 2Yes
Degree of protection (IP)IP20
Voltage protection level L-N1.6kV
Nominal voltage DC-V
Signalling at the deviceOptic
Number of conductors (without earthing)4
Voltage protection level N-PE1.8kV
System configuration TTNo
Mounting methodDIN rail (top hat rail) 35 mm
System configuration TN-SNo
Voltage protection level1.8kV
With remote signalling contactYes
Max. continuous voltage AC460V
Max. conductor cross section solid (solid, stranded)25mm²
System configuration DCNo
Integrated backup fuseNo
Construction size4 modular spacing
Max. continuous voltage DC-V
System configuration ITYes
Nominal voltage AC400V
System configuration TN-CNo
System configuration TNNo
Max. conductor cross section flexible (fine-strand)16mm²
Max. PV-voltage-V
System configuration otherNo
Short-circuit breaking capacity (Isccr)50kA
Max. discharge surge current (8/20)20kA
Leakage-current freeNo
Max. overcurrent protection device, parallel connection (fuse)40A
Integrated short-circuit protectionNo
System configuration TN-C-SNo
Max. overcurrent protection device, series connection (fuse)80A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9L20421

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Nominal discharge surge current (8/20)

5kA

Category type 2

Degree of protection (IP)

IP20

Voltage protection level L-N

1.6kV

Nominal voltage DC

-V

Signalling at the device

Optic

Number of conductors (without earthing)

4

Voltage protection level N-PE

1.8kV

System configuration TT

Mounting method

DIN rail (top hat rail) 35 mm

System configuration TN-S

Voltage protection level

1.8kV

With remote signalling contact

Max. continuous voltage AC

460V

Max. conductor cross section solid (solid, stranded)

25mm²

System configuration DC

Integrated backup fuse

Construction size

4 modular spacing

Max. continuous voltage DC

-V

System configuration IT

Nominal voltage AC

400V

System configuration TN-C

System configuration TN

Max. conductor cross section flexible (fine-strand)

16mm²

Max. PV-voltage

-V

System configuration other

Short-circuit breaking capacity (Isccr)

50kA

Max. discharge surge current (8/20)

20kA

Leakage-current free

Max. overcurrent protection device, parallel connection (fuse)

40A

Integrated short-circuit protection

System configuration TN-C-S

Max. overcurrent protection device, series connection (fuse)

80A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.