Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height325mm
Width45mm
Number of analogue inputs3
Number of digital inputs6
With control elementYes
Depth245mm
Number of analogue outputs1
Number of digital outputs1
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPNo
Number of HW-interfaces other1
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
With optical interfaceNo
Max. output frequency599Hz
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Mains voltage200 - 240V
Supporting protocol for PROFIBUSYes
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Supporting protocol for CANYes
Supporting protocol for other bus systemsYes
Application in domestic- and commercial area permittedNo
Mains frequency50/60 Hz
Number of phases input1
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Number of phases output3
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Application in industrial area permittedYes
Integrated breaking resistanceNo
Number of interfaces PROFINET0
Supporting protocol for DeviceNetYes
Type of converterU converter
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Max. output at linear load at rated output voltage0.18kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage0.18kW
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance5%
Nominal output current I2N1.5A
Supporting protocol for PROFINET IOYes
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage240V
Supporting protocol for Foundation FieldbusNo
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U02M2B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

325mm

Width

45mm

Number of analogue inputs

3

Number of digital inputs

6

With control element

Depth

245mm

Number of analogue outputs

1

Number of digital outputs

1

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

With optical interface

Max. output frequency

599Hz

Supporting protocol for ASI

Supporting protocol for Data-Highway

Mains voltage

200 .. 240V

Supporting protocol for PROFIBUS

4-quadrant operation possible

Supporting protocol for SERCOS

Supporting protocol for CAN

Supporting protocol for other bus systems

Application in domestic- and commercial area permitted

Mains frequency

50/60 Hz

Number of phases input

1

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Number of phases output

3

With PC connection

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Application in industrial area permitted

Integrated breaking resistance

Number of interfaces PROFINET

0

Supporting protocol for DeviceNet

Type of converter

U converter

Supporting protocol for Modbus

Supporting protocol for KNX

Max. output at linear load at rated output voltage

0.18kW

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

0.18kW

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

5%

Nominal output current I2N

1.5A

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

240V

Supporting protocol for Foundation Fieldbus

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.