Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs6
Height325mm
Width60mm
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of analogue inputs3
Supporting protocol for ASINo
Number of analogue outputs1
Number of HW-interfaces RS-2320
Number of digital outputs1
Depth245mm
With optical interfaceNo
With control elementYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPNo
Number of HW-interfaces other1
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Mains frequency50/60 Hz
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
With PC connectionYes
Mains voltage380 - 500V
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Relative symmetric net voltage tolerance10%
Application in industrial area permittedYes
Max. output at linear load at rated output voltage3kW
Max. output frequency599Hz
Number of phases input3
Number of phases output3
Application in domestic- and commercial area permittedNo
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage3kW
Number of interfaces PROFINET0
Type of converterU converter
4-quadrant operation possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance5%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo
Max. output voltage500V
Nominal output current I2N7.1A
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U30N4B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs

6

Height

325mm

Width

60mm

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of analogue inputs

3

Supporting protocol for ASI

Number of analogue outputs

1

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Depth

245mm

With optical interface

With control element

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Mains frequency

50/60 Hz

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

With PC connection

Mains voltage

380 .. 500V

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Relative symmetric net voltage tolerance

10%

Application in industrial area permitted

Max. output at linear load at rated output voltage

3kW

Max. output frequency

599Hz

Number of phases input

3

Number of phases output

3

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

3kW

Number of interfaces PROFINET

0

Type of converter

U converter

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

5%

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Max. output voltage

500V

Nominal output current I2N

7.1A

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.