Aleta.hr
Main Product Image

ATV320U40N4C

Code: 1757121

ManufacturerSchneider
Catalog numberATV320U40N4C
Type
EAN code3606480966781

















Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage380 - 500V
Max. output voltage500V
Number of analogue inputs3
Max. output at linear load at rated output voltage4kW
Number of phases output3
Number of phases input3
Supporting protocol for CANYes
Mains frequency50/60 Hz
Relative symmetric net frequency tolerance5%
Max. output at quadratic load at rated output voltage4kW
Supporting protocol for TCP/IPNo
Nominal output current I2N9.5A
Number of analogue outputs1
Application in industrial area permittedYes
Number of digital inputs6
Relative symmetric net voltage tolerance10%
Supporting protocol for INTERBUSNo
Max. output frequency599Hz
Supporting protocol for PROFIBUSYes
With control elementYes
Application in domestic- and commercial area permittedNo
Number of digital outputs1
With optical interfaceNo
4-quadrant operation possibleYes
With PC connectionYes
Type of converterU converter
Integrated breaking resistanceNo
Degree of protection (NEMA)1
Degree of protection (IP)IP20
Height184mm
Width140mm
Depth158mm
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetYes
Supporting protocol for LONNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Number of HW-interfaces industrial Ethernet1
Supporting protocol for other bus systemsYes
Number of interfaces PROFINET0
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Number of HW-interfaces parallel0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U40N4C

Main Product Image

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

380 .. 500V

Max. output voltage

500V

Number of analogue inputs

3

Max. output at linear load at rated output voltage

4kW

Number of phases output

3

Number of phases input

3

Supporting protocol for CAN

Mains frequency

50/60 Hz

Relative symmetric net frequency tolerance

5%

Max. output at quadratic load at rated output voltage

4kW

Supporting protocol for TCP/IP

Nominal output current I2N

9.5A

Number of analogue outputs

1

Application in industrial area permitted

Number of digital inputs

6

Relative symmetric net voltage tolerance

10%

Supporting protocol for INTERBUS

Max. output frequency

599Hz

Supporting protocol for PROFIBUS

With control element

Application in domestic- and commercial area permitted

Number of digital outputs

1

With optical interface

4-quadrant operation possible

With PC connection

Type of converter

U converter

Integrated breaking resistance

Degree of protection (NEMA)

1

Degree of protection (IP)

IP20

Height

184mm

Width

140mm

Depth

158mm

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for other bus systems

Number of interfaces PROFINET

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.