Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs8
Number of analogue inputs3
Supporting protocol for LONNo
Number of analogue outputs2
Number of HW-interfaces RS-4220
Width213mm
Height660mm
Number of digital outputs1
Number of HW-interfaces industrial Ethernet2
Number of HW-interfaces RS-2320
Depth262mm
With control elementNo
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
With PC connectionYes
Mains frequency50/60 Hz
Mains voltage380 - 480V
Supporting protocol for KNXNo
Application in domestic- and commercial area permittedNo
Number of phases input3
Integrated breaking resistanceNo
Number of phases output3
Type of converterU converter
Max. output frequency500Hz
Application in industrial area permittedYes
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage45kW
Degree of protection (NEMA)1
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Max. output voltage480V
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage45kW
Supporting protocol for PROFIsafeNo
Relative symmetric net frequency tolerance5%
Nominal output current I2N79.8A
Supporting protocol for BACnetNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV340D37N4E

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs

8

Number of analogue inputs

3

Supporting protocol for LON

Number of analogue outputs

2

Number of HW-interfaces RS-422

0

Width

213mm

Height

660mm

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

2

Number of HW-interfaces RS-232

0

Depth

262mm

With control element

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

With optical interface

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

1

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for ASI

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

4-quadrant operation possible

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for SUCONET

With PC connection

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

Supporting protocol for KNX

Application in domestic- and commercial area permitted

Number of phases input

3

Integrated breaking resistance

Number of phases output

3

Type of converter

U converter

Max. output frequency

500Hz

Application in industrial area permitted

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

45kW

Degree of protection (NEMA)

1

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Max. output voltage

480V

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

45kW

Supporting protocol for PROFIsafe

Relative symmetric net frequency tolerance

5%

Nominal output current I2N

79.8A

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.