Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height908mm
Width271mm
Depth309mm
Number of digital inputs8
Number of digital outputs1
With control elementNo
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet2
Number of HW-interfaces RS-4851
Number of analogue outputs2
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPYes
With optical interfaceNo
Number of HW-interfaces serial TTY0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-2320
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Number of analogue inputs3
Supporting protocol for CANNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Number of HW-interfaces other1
Number of HW-interfaces parallel0
With PC connectionYes
Degree of protection (IP)IP20
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Number of phases input3
Mains frequency50/60 Hz
4-quadrant operation possibleYes
Number of interfaces PROFINET0
Application in industrial area permittedYes
Mains voltage380 - 480V
Max. output at linear load at rated output voltage75kW
Max. output at quadratic load at rated output voltage75kW
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance5%
Type of converterU converter
Application in domestic- and commercial area permittedNo
Relative symmetric net voltage tolerance10%
Max. output frequency500Hz
Integrated breaking resistanceNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Number of phases output3
Max. output voltage480V
Supporting protocol for BACnetNo
Degree of protection (NEMA)1
Nominal output current I2N131.3A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV340D55N4E

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

908mm

Width

271mm

Depth

309mm

Number of digital inputs

8

Number of digital outputs

1

With control element

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

2

Number of HW-interfaces RS-485

1

Number of analogue outputs

2

Supporting protocol for ASI

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces serial TTY

0

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-232

0

Supporting protocol for INTERBUS

Supporting protocol for KNX

Number of analogue inputs

3

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

With PC connection

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Number of phases input

3

Mains frequency

50/60 Hz

4-quadrant operation possible

Number of interfaces PROFINET

0

Application in industrial area permitted

Mains voltage

380 .. 480V

Max. output at linear load at rated output voltage

75kW

Max. output at quadratic load at rated output voltage

75kW

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

5%

Type of converter

U converter

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Max. output frequency

500Hz

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Number of phases output

3

Max. output voltage

480V

Supporting protocol for BACnet

Degree of protection (NEMA)

1

Nominal output current I2N

131.3A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.