Technical specifications

Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4851
Number of analogue outputs1
Width85mm
Number of HW-interfaces industrial Ethernet2
Number of digital outputs2
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of analogue inputs2
Height270mm
Number of HW-interfaces parallel0
Number of digital inputs5
Depth232.5mm
With optical interfaceNo
Supporting protocol for LONNo
With control elementNo
Number of HW-interfaces USB0
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Mains voltage380 - 480V
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Type of converterU converter
Application in industrial area permittedYes
Application in domestic- and commercial area permittedNo
Mains frequency50/60 Hz
Degree of protection (IP)IP20
Max. output frequency599Hz
Supporting protocol for INTERBUS-SafetyNo
Number of phases input3
Max. output at linear load at rated output voltage2.2kW
Number of phases output3
Integrated breaking resistanceNo
With PC connectionYes
Supporting protocol for Data-HighwayNo
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage2.2kW
Relative symmetric net frequency tolerance5%
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N5.1A
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Max. output voltage480V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV340U15N4E | Frek. Pret. 1.5kW- 400V 3PH ATV340 Eth.

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Number of analogue outputs

1

Width

85mm

Number of HW-interfaces industrial Ethernet

2

Number of digital outputs

2

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Height

270mm

Number of HW-interfaces parallel

0

Number of digital inputs

5

Depth

232.5mm

With optical interface

Supporting protocol for LON

With control element

Number of HW-interfaces USB

0

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Mains voltage

380 .. 480V

4-quadrant operation possible

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Type of converter

U converter

Application in industrial area permitted

Application in domestic- and commercial area permitted

Mains frequency

50/60 Hz

Degree of protection (IP)

IP20

Max. output frequency

599Hz

Supporting protocol for INTERBUS-Safety

Number of phases input

3

Max. output at linear load at rated output voltage

2.2kW

Number of phases output

3

Integrated breaking resistance

With PC connection

Supporting protocol for Data-Highway

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

2.2kW

Relative symmetric net frequency tolerance

5%

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

5.1A

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Max. output voltage