Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width85mm
Number of analogue inputs3
Number of digital inputs8
Number of digital outputs1
With control elementNo
Height270mm
Depth232.5mm
With optical interfaceNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4220
Number of analogue outputs2
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Supporting protocol for CANNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Supporting protocol for KNXNo
Supporting protocol for ASINo
Number of HW-interfaces RS-4851
Supporting protocol for Data-HighwayNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
Number of HW-interfaces industrial Ethernet2
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Supporting protocol for other bus systemsNo
Degree of protection (IP)IP20
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Mains voltage380 - 480V
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
Max. output at linear load at rated output voltage4kW
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Type of converterU converter
Max. output frequency599Hz
Max. output at quadratic load at rated output voltage4kW
Relative symmetric net frequency tolerance5%
Supporting protocol for EtherNet/IPYes
Application in domestic- and commercial area permittedNo
Integrated breaking resistanceNo
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N8.6A
Max. output voltage480V
Supporting protocol for PROFINET IONo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV340U30N4E

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

85mm

Number of analogue inputs

3

Number of digital inputs

8

Number of digital outputs

1

With control element

Height

270mm

Depth

232.5mm

With optical interface

Supporting protocol for TCP/IP

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Supporting protocol for LON

Supporting protocol for CAN

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Supporting protocol for KNX

Supporting protocol for ASI

Number of HW-interfaces RS-485

1

Supporting protocol for Data-Highway

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

1

Number of HW-interfaces industrial Ethernet

2

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

Degree of protection (IP)

IP20

4-quadrant operation possible

Supporting protocol for SERCOS

Mains voltage

380 .. 480V

With PC connection

Supporting protocol for INTERBUS-Safety

Number of phases output

3

Max. output at linear load at rated output voltage

4kW

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Type of converter

U converter

Max. output frequency

599Hz

Max. output at quadratic load at rated output voltage

4kW

Relative symmetric net frequency tolerance

5%

Supporting protocol for EtherNet/IP

Application in domestic- and commercial area permitted

Integrated breaking resistance

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

8.6A

Max. output voltage

480V

Supporting protocol for PROFINET IO

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.