Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for LONNo
Number of analogue inputs3
Depth232.5mm
With control elementNo
Width85mm
Number of HW-interfaces parallel0
Number of analogue outputs2
Height270mm
Number of HW-interfaces RS-2320
Number of digital outputs1
Number of HW-interfaces serial TTY0
Number of digital inputs8
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
With optical interfaceNo
Number of HW-interfaces other1
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPNo
Supporting protocol for CANYes
Degree of protection (IP)IP20
With PC connectionYes
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
Mains voltage380 - 480V
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedNo
Max. output at quadratic load at rated output voltage4kW
Number of phases output3
Integrated breaking resistanceNo
Mains frequency50/60 Hz
Type of converterU converter
Max. output frequency599Hz
Relative symmetric net frequency tolerance5%
Number of phases input3
Application in industrial area permittedYes
Max. output at linear load at rated output voltage4kW
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Nominal output current I2N11.4A
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Supporting protocol for PROFINET IOYes
Max. output voltage480V
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV340U40N4 | Frek. Pret. 4kW- 400V 3PH ATV340

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for LON

Number of analogue inputs

3

Depth

232.5mm

With control element

Width

85mm

Number of HW-interfaces parallel

0

Number of analogue outputs

2

Height

270mm

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Number of HW-interfaces serial TTY

0

Number of digital inputs

8

Number of HW-interfaces USB

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for ASI

Supporting protocol for INTERBUS

With optical interface

Number of HW-interfaces other

1

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for CAN

Degree of protection (IP)

IP20

With PC connection

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Mains voltage

380 .. 480V

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

4-quadrant operation possible

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

4kW

Number of phases output

3

Integrated breaking resistance

Mains frequency

50/60 Hz

Type of converter

U converter

Max. output frequency

599Hz

Relative symmetric net frequency tolerance

5%

Number of phases input

3

Application in industrial area permitted

Max. output at linear load at rated output voltage

4kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Nominal output current I2N

11.4A

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Max. output voltage

480V

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus