Technical specifications

Number of digital inputs6
Depth377mm
Width595mm
Height1190mm
With control elementYes
Number of analogue outputs2
Number of analogue inputs3
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of digital outputs0
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
With optical interfaceYes
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANNo
Degree of protection (IP)IP00
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Mains frequency50/60 Hz
Type of converterU converter
Mains voltage380 - 480V
Integrated breaking resistanceNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of phases input3
With PC connectionNo
4-quadrant operation possibleYes
Number of interfaces PROFINET0
Number of phases output3
Max. output at linear load at rated output voltage250kW
Max. output frequency500Hz
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Relative symmetric net frequency tolerance5%
Max. output at quadratic load at rated output voltage250kW
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Max. output voltage480V
Nominal output current I2N481A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630C25N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs

6

Depth

377mm

Width

595mm

Height

1190mm

With control element

Number of analogue outputs

2

Number of analogue inputs

3

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of digital outputs

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

With optical interface

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Degree of protection (IP)

IP00

Supporting protocol for KNX

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Mains frequency

50/60 Hz

Type of converter

U converter

Mains voltage

380 .. 480V

Integrated breaking resistance

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Number of phases input

3

With PC connection

4-quadrant operation possible

Number of interfaces PROFINET

0

Number of phases output

3

Max. output at linear load at rated output voltage

250kW

Max. output frequency

500Hz

Application in industrial area permitted

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Relative symmetric net frequency tolerance

5%

Max. output at quadratic load at rated output voltage

250kW

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Max. output voltage

480V

Nominal output current I2N

481A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.