Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces RS-2320
Number of digital inputs8
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Depth393mm
Number of analogue outputs2
With control elementYes
Number of HW-interfaces industrial Ethernet0
Height852mm
Number of digital outputs1
Number of analogue inputs3
Width320mm
Supporting protocol for PROFIBUSYes
Number of HW-interfaces USB0
Supporting protocol for SUCONETNo
Degree of protection (IP)IP00
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANYes
Supporting protocol for ModbusNo
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Number of HW-interfaces other0
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4853
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
With PC connectionNo
4-quadrant operation possibleYes
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Mains voltage380 - 480V
Type of converterU converter
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases input3
Integrated breaking resistanceNo
Supporting protocol for PROFINET IOYes
Max. output frequency500Hz
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Number of phases output3
Supporting protocol for Foundation FieldbusNo
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage132kW
Max. output at quadratic load at rated output voltage132kW
Relative symmetric net frequency tolerance5%
Max. output voltage480V
Supporting protocol for BACnetNo
Nominal output current I2N250A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930C13N4C | Frek.pret. IP00 130KW 400v/480v BEZ Chp.

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces RS-232

0

Number of digital inputs

8

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Depth

393mm

Number of analogue outputs

2

With control element

Number of HW-interfaces industrial Ethernet

0

Height

852mm

Number of digital outputs

1

Number of analogue inputs

3

Width

320mm

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for SUCONET

Degree of protection (IP)

IP00

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for Modbus

With optical interface

Supporting protocol for ASI

Supporting protocol for KNX

Number of HW-interfaces other

0

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

3

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

With PC connection

4-quadrant operation possible

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Mains voltage

380 .. 480V

Type of converter

U converter

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Number of phases input

3

Integrated breaking resistance

Supporting protocol for PROFINET IO

Max. output frequency

500Hz

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Number of phases output

3

Supporting protocol for Foundation Fieldbus

Application in industrial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

132kW

Max. output at quadratic load at rated output voltage

132kW

Relative symmetric net frequency tolerance

5%

Max. output voltage

480V

Supporting protocol for BACnet

Nominal output current I2N

250A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.