Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage200 - 240V
Max. output voltage240V
Mains frequency50/60 Hz
Max. output frequency500Hz
Number of phases output3
Number of phases input3
Max. output at quadratic load at rated output voltage18.5kW
Max. output at linear load at rated output voltage18.5kW
Nominal output current I2N78.4A
Relative symmetric net voltage tolerance10%
Number of digital outputs1
Number of analogue outputs2
Supporting protocol for TCP/IPNo
Number of digital inputs8
Application in industrial area permittedYes
Number of analogue inputs3
Relative symmetric net frequency tolerance5%
Supporting protocol for PROFIBUSYes
Supporting protocol for KNXNo
With control elementYes
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNetYes
Supporting protocol for PROFINET IOYes
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for BACnetNo
Number of HW-interfaces RS-2320
Supporting protocol for INTERBUSNo
Supporting protocol for EtherNet/IPYes
Number of HW-interfaces RS-4220
Number of interfaces PROFINET0
Number of HW-interfaces parallel0
Supporting protocol for other bus systemsYes
Number of HW-interfaces RS-4853
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SUCONETNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for SafetyBUS pNo
With PC connectionNo
Number of HW-interfaces industrial Ethernet0
Integrated breaking resistanceNo
4-quadrant operation possibleYes
Type of converterU converter
Degree of protection (IP)IP21
Width226mm
With optical interfaceNo
Height673mm
Depth274mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D18M3

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

200 .. 240V

Max. output voltage

240V

Mains frequency

50/60 Hz

Max. output frequency

500Hz

Number of phases output

3

Number of phases input

3

Max. output at quadratic load at rated output voltage

18.5kW

Max. output at linear load at rated output voltage

18.5kW

Nominal output current I2N

78.4A

Relative symmetric net voltage tolerance

10%

Number of digital outputs

1

Number of analogue outputs

2

Supporting protocol for TCP/IP

Number of digital inputs

8

Application in industrial area permitted

Number of analogue inputs

3

Relative symmetric net frequency tolerance

5%

Supporting protocol for PROFIBUS

Supporting protocol for KNX

With control element

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for CAN

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for BACnet

Number of HW-interfaces RS-232

0

Supporting protocol for INTERBUS

Supporting protocol for EtherNet/IP

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Number of HW-interfaces parallel

0

Supporting protocol for other bus systems

Number of HW-interfaces RS-485

3

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for SUCONET

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Supporting protocol for SafetyBUS p

With PC connection

Number of HW-interfaces industrial Ethernet

0

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Degree of protection (IP)

IP21

Width

226mm

With optical interface

Height

673mm

Depth

274mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.