Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces industrial Ethernet0
With control elementYes
Depth325.5mm
Number of digital outputs1
Number of analogue inputs3
Width290mm
Number of digital inputs8
Supporting protocol for LONNo
Number of analogue outputs2
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4853
Height922mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP21
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
4-quadrant operation possibleYes
Supporting protocol for ModbusNo
Number of phases output3
Type of converterU converter
Number of phases input3
Integrated breaking resistanceNo
With PC connectionNo
Supporting protocol for other bus systemsYes
Mains voltage200 - 240V
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Application in industrial area permittedYes
Max. output frequency500Hz
Max. output at linear load at rated output voltage37kW
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFINET CBANo
Relative symmetric net frequency tolerance5%
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Max. output voltage240V
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Nominal output current I2N149A
Max. output at quadratic load at rated output voltage37kW
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D37M3C | Frek. Pret. IP21 37KW 200v/240v BEZ Chp.

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces industrial Ethernet

0

With control element

Depth

325.5mm

Number of digital outputs

1

Number of analogue inputs

3

Width

290mm

Number of digital inputs

8

Supporting protocol for LON

Number of analogue outputs

2

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

3

Height

922mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for DeviceNet

Degree of protection (IP)

IP21

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for PROFIBUS

4-quadrant operation possible

Supporting protocol for Modbus

Number of phases output

3

Type of converter

U converter

Number of phases input

3

Integrated breaking resistance

With PC connection

Supporting protocol for other bus systems

Mains voltage

200 .. 240V

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Application in industrial area permitted

Max. output frequency

500Hz

Max. output at linear load at rated output voltage

37kW

Application in domestic- and commercial area permitted

Supporting protocol for PROFINET CBA

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Max. output voltage

240V

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for DeviceNet Safety

Nominal output current I2N

149A

Max. output at quadratic load at rated output voltage

37kW

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.