Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width290mm
Height922mm
Number of digital inputs8
Number of analogue outputs2
Depth325.5mm
Number of digital outputs1
With control elementYes
Number of analogue inputs3
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4853
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces other0
Number of HW-interfaces USB0
With optical interfaceYes
Number of HW-interfaces parallel0
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Supporting protocol for PROFIBUSYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPNo
With PC connectionNo
Degree of protection (IP)IP21
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for ModbusNo
Number of interfaces PROFINET0
Type of converterU converter
Mains frequency50/60 Hz
Mains voltage380 - 480V
Max. output at quadratic load at rated output voltage55kW
4-quadrant operation possibleYes
Max. output frequency500Hz
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Supporting protocol for PROFIsafeNo
Number of phases input3
Relative symmetric net frequency tolerance5%
Max. output at linear load at rated output voltage55kW
Supporting protocol for EtherNet/IPYes
Number of phases output3
Application in industrial area permittedYes
Supporting protocol for PROFINET IOYes
Supporting protocol for DeviceNet SafetyNo
Max. output voltage480V
Nominal output current I2N106A
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D55N4 | Frek. Pret. IP21 55KW 400v/480v

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

290mm

Height

922mm

Number of digital inputs

8

Number of analogue outputs

2

Depth

325.5mm

Number of digital outputs

1

With control element

Number of analogue inputs

3

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

3

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

With PC connection

Degree of protection (IP)

IP21

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for Modbus

Number of interfaces PROFINET

0

Type of converter

U converter

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

Max. output at quadratic load at rated output voltage

55kW

4-quadrant operation possible

Max. output frequency

500Hz

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Integrated breaking resistance

Supporting protocol for PROFIsafe

Number of phases input

3

Relative symmetric net frequency tolerance

5%

Max. output at linear load at rated output voltage

55kW

Supporting protocol for EtherNet/IP

Number of phases output

3

Application in industrial area permitted

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Max. output voltage

480V

Nominal output current I2N

106A

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.