Technical specifications

Depth325.5mm
Number of digital inputs8
Height922mm
Width290mm
With control elementYes
Number of HW-interfaces RS-2320
Number of digital outputs1
Number of analogue outputs2
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for PROFIBUSYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4853
With optical interfaceYes
Number of HW-interfaces parallel0
Supporting protocol for CANYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for KNXNo
Number of analogue inputs3
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP21
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Supporting protocol for SUCONETNo
With PC connectionNo
Number of phases output3
Supporting protocol for SERCOSNo
Supporting protocol for DeviceNet SafetyNo
Number of interfaces PROFINET0
Mains voltage380 - 480V
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage90kW
Mains frequency50/60 Hz
Max. output frequency500Hz
Relative symmetric net frequency tolerance5%
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage90kW
Integrated breaking resistanceNo
4-quadrant operation possibleYes
Number of phases input3
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Type of converterU converter
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Nominal output current I2N173A
Max. output voltage480V
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D90N4 | Frek. Pret. IP21 90KW 400v/480v

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

325.5mm

Number of digital inputs

8

Height

922mm

Width

290mm

With control element

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Number of analogue outputs

2

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

3

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for KNX

Number of analogue inputs

3

Supporting protocol for TCP/IP

Degree of protection (IP)

IP21

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for ASI

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Supporting protocol for SUCONET

With PC connection

Number of phases output

3

Supporting protocol for SERCOS

Supporting protocol for DeviceNet Safety

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

90kW

Mains frequency

50/60 Hz

Max. output frequency

500Hz

Relative symmetric net frequency tolerance

5%

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

90kW

Integrated breaking resistance

4-quadrant operation possible

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Type of converter

U converter

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Nominal output current I2N

173A

Max. output voltage

480V

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.