Technical specifications

Width144mm
Depth206mm
Height350mm
Number of digital inputs8
With control elementYes
Number of analogue outputs2
Number of digital outputs1
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Supporting protocol for DeviceNetYes
Number of HW-interfaces RS-2320
Number of HW-interfaces other0
Number of HW-interfaces serial TTY0
Supporting protocol for ModbusNo
Number of analogue inputs3
Supporting protocol for ASINo
With optical interfaceYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4853
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Supporting protocol for CANYes
Degree of protection (IP)IP21
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUS-SafetyNo
With PC connectionNo
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Mains voltage380 - 480V
Type of converterU converter
Supporting protocol for PROFINET CBANo
Integrated breaking resistanceNo
Supporting protocol for PROFINET IOYes
Relative symmetric net frequency tolerance5%
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for DeviceNet SafetyNo
Number of phases input3
Supporting protocol for Foundation FieldbusNo
Number of interfaces PROFINET0
Max. output frequency500Hz
Relative symmetric net voltage tolerance10%
4-quadrant operation possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases output3
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage1.5kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N4A
Max. output voltage480V
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930U15N4 | Frek. Pret. ATV930 IP21 1,5KW 400/480V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

144mm

Depth

206mm

Height

350mm

Number of digital inputs

8

With control element

Number of analogue outputs

2

Number of digital outputs

1

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for DeviceNet

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

0

Number of HW-interfaces serial TTY

0

Supporting protocol for Modbus

Number of analogue inputs

3

Supporting protocol for ASI

With optical interface

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

3

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Supporting protocol for CAN

Degree of protection (IP)

IP21

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

With PC connection

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

Type of converter

U converter

Supporting protocol for PROFINET CBA

Integrated breaking resistance

Supporting protocol for PROFINET IO

Relative symmetric net frequency tolerance

5%

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for DeviceNet Safety

Number of phases input

3

Supporting protocol for Foundation Fieldbus

Number of interfaces PROFINET

0

Max. output frequency

500Hz

Relative symmetric net voltage tolerance

10%

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Number of phases output

3

Application in domestic- and commercial area permitted

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

1.5kW

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Nominal output current I2N

4A

Max. output voltage

480V

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.