Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue outputs2
Height409mm
Number of analogue inputs3
Number of digital outputs1
Number of digital inputs8
Width171mm
With control elementYes
Depth236mm
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-4853
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for other bus systemsYes
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces other0
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for ASINo
With optical interfaceNo
With PC connectionNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP21
Relative symmetric net voltage tolerance10%
Mains voltage200 - 240V
Integrated breaking resistanceNo
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedYes
Max. output voltage240V
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency500Hz
Application in industrial area permittedYes
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance5%
Number of phases output3
Number of interfaces PROFINET0
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage5.5kW
Supporting protocol for PROFINET CBANo
Type of converterU converter
Nominal output current I2N25.4A
Supporting protocol for DeviceNet SafetyNo
Max. output at linear load at rated output voltage5.5kW
Mains frequency50/60 Hz
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930U55M3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue outputs

2

Height

409mm

Number of analogue inputs

3

Number of digital outputs

1

Number of digital inputs

8

Width

171mm

With control element

Depth

236mm

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

3

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for other bus systems

Supporting protocol for TCP/IP

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Number of HW-interfaces other

0

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for Modbus

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for ASI

With optical interface

With PC connection

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Degree of protection (IP)

IP21

Relative symmetric net voltage tolerance

10%

Mains voltage

200 .. 240V

Integrated breaking resistance

4-quadrant operation possible

Application in domestic- and commercial area permitted

Max. output voltage

240V

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

500Hz

Application in industrial area permitted

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

5%

Number of phases output

3

Number of interfaces PROFINET

0

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

5.5kW

Supporting protocol for PROFINET CBA

Type of converter

U converter

Nominal output current I2N

25.4A

Supporting protocol for DeviceNet Safety

Max. output at linear load at rated output voltage

5.5kW

Mains frequency

50/60 Hz

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.