Width600mm
With control elementYes
Number of HW-interfaces parallel0
Depth669mm
With optical interfaceNo
Number of HW-interfaces USB0
Number of analogue inputs3
Number of HW-interfaces RS-2320
Number of digital inputs8
Supporting protocol for PROFIBUSYes
Height2350mm
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for ModbusNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4853
Supporting protocol for Data-HighwayNo
Number of HW-interfaces other0
Number of digital outputs1
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Supporting protocol for ASINo
Number of analogue outputs2
Supporting protocol for DeviceNetYes
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Mains voltage380 - 440V
Supporting protocol for INTERBUS-SafetyNo
Max. output frequency500Hz
Mains frequency50/60 Hz
Type of converterU converter
Degree of protection (IP)IP54
Application in industrial area permittedYes
Number of phases output3
Number of phases input3
Supporting protocol for SUCONETNo
Integrated breaking resistanceNo
Supporting protocol for other bus systemsYes
With PC connectionNo
Application in domestic- and commercial area permittedYes
Number of interfaces PROFINET0
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage200kW
Max. output at linear load at rated output voltage200kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance5%
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Max. output voltage440V
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N370A
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950C20N4F | Frek. Pret. IP54 200KW 400/480V u Ormaru

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

600mm

With control element

Number of HW-interfaces parallel

0

Depth

669mm

With optical interface

Number of HW-interfaces USB

0

Number of analogue inputs

3

Number of HW-interfaces RS-232

0

Number of digital inputs

8

Supporting protocol for PROFIBUS

Height

2350mm

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

3

Supporting protocol for Data-Highway

Number of HW-interfaces other

0

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Supporting protocol for ASI

Number of analogue outputs

2

Supporting protocol for DeviceNet

4-quadrant operation possible

Supporting protocol for SERCOS

Mains voltage

380 .. 440V

Supporting protocol for INTERBUS-Safety

Max. output frequency

500Hz

Mains frequency

50/60 Hz

Type of converter

U converter

Degree of protection (IP)

IP54

Application in industrial area permitted

Number of phases output

3

Number of phases input

3

Supporting protocol for SUCONET

Integrated breaking resistance

Supporting protocol for other bus systems

With PC connection

Application in domestic- and commercial area permitted

Number of interfaces PROFINET

0

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

200kW

Max. output at linear load at rated output voltage

200kW

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

5%

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Max. output voltage

440V

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Nominal output current I2N

370A

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.