Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height678mm
Width264mm
Depth299mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of analogue inputs3
Number of analogue outputs2
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4853
With control elementYes
Number of HW-interfaces other0
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for CANYes
Number of HW-interfaces industrial Ethernet0
Supporting protocol for PROFIBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
With optical interfaceNo
Supporting protocol for DeviceNetYes
Number of digital inputs8
Supporting protocol for ModbusNo
Number of digital outputs1
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
With PC connectionNo
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage11kW
Supporting protocol for Foundation FieldbusNo
Degree of protection (IP)IP55
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance5%
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Number of phases input3
Max. output at linear load at rated output voltage11kW
Integrated breaking resistanceNo
Number of phases output3
Type of converterU converter
Max. output frequency500Hz
Mains voltage380 - 480V
4-quadrant operation possibleYes
Supporting protocol for EtherNet/IPYes
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for other bus systemsYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output voltage480V
Supporting protocol for BACnetNo
Nominal output current I2N23.5A
Supporting protocol for PROFINET IOYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950D11N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

678mm

Width

264mm

Depth

299mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of analogue inputs

3

Number of analogue outputs

2

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

3

With control element

Number of HW-interfaces other

0

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for CAN

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

With optical interface

Supporting protocol for DeviceNet

Number of digital inputs

8

Supporting protocol for Modbus

Number of digital outputs

1

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

With PC connection

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

11kW

Supporting protocol for Foundation Fieldbus

Degree of protection (IP)

IP55

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Number of phases input

3

Max. output at linear load at rated output voltage

11kW

Integrated breaking resistance

Number of phases output

3

Type of converter

U converter

Max. output frequency

500Hz

Mains voltage

380 .. 480V

4-quadrant operation possible

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output voltage

480V

Supporting protocol for BACnet

Nominal output current I2N

23.5A

Supporting protocol for PROFINET IO

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.