Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width290mm
Number of digital inputs8
With control elementYes
Depth401mm
Height910mm
Number of analogue outputs2
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of analogue inputs3
Number of digital outputs1
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Number of HW-interfaces serial TTY0
Degree of protection (IP)IP55
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Number of HW-interfaces RS-4853
Supporting protocol for ModbusNo
With optical interfaceNo
Supporting protocol for SUCONETNo
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
With PC connectionNo
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380 - 480V
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Type of converterU converter
Number of phases input3
Relative symmetric net frequency tolerance5%
Number of phases output3
Max. output at linear load at rated output voltage30kW
Max. output at quadratic load at rated output voltage30kW
Max. output frequency500Hz
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceNo
Supporting protocol for PROFINET IOYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Max. output voltage480V
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Nominal output current I2N61.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950D30N4E | ATV950 IP55 30KW 400v/480v s Sklopkom

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

290mm

Number of digital inputs

8

With control element

Depth

401mm

Height

910mm

Number of analogue outputs

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of analogue inputs

3

Number of digital outputs

1

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Degree of protection (IP)

IP55

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for DeviceNet

Number of HW-interfaces RS-485

3

Supporting protocol for Modbus

With optical interface

Supporting protocol for SUCONET

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

With PC connection

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

Mains voltage

380 .. 480V

4-quadrant operation possible

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Type of converter

U converter

Number of phases input

3

Relative symmetric net frequency tolerance

5%

Number of phases output

3

Max. output at linear load at rated output voltage

30kW

Max. output at quadratic load at rated output voltage

30kW

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Max. output voltage

480V

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Nominal output current I2N

61.5A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.