Technical specifications

Number of digital outputs1
Width345mm
Number of digital inputs8
With control elementYes
Depth436mm
Height1250mm
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4853
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of analogue outputs2
Number of analogue inputs3
Supporting protocol for CANYes
Supporting protocol for KNXNo
Mains voltage380 - 480V
Supporting protocol for INTERBUSNo
Number of phases output3
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP55
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Data-HighwayNo
With optical interfaceNo
Mains frequency50/60 Hz
4-quadrant operation possibleYes
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Type of converterU converter
Number of HW-interfaces parallel0
Supporting protocol for DeviceNetYes
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Number of interfaces PROFINET0
With PC connectionNo
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for other bus systemsYes
Number of phases input3
Integrated breaking resistanceNo
Nominal output current I2N145A
Max. output at quadratic load at rated output voltage75kW
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo
Max. output voltage480V
Max. output frequency500Hz
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance5%
Max. output at linear load at rated output voltage75kW
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950D75N4E

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs

1

Width

345mm

Number of digital inputs

8

With control element

Depth

436mm

Height

1250mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

3

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Number of analogue outputs

2

Number of analogue inputs

3

Supporting protocol for CAN

Supporting protocol for KNX

Mains voltage

380 .. 480V

Supporting protocol for INTERBUS

Number of phases output

3

Supporting protocol for TCP/IP

Degree of protection (IP)

IP55

Supporting protocol for INTERBUS-Safety

Supporting protocol for Data-Highway

With optical interface

Mains frequency

50/60 Hz

4-quadrant operation possible

Supporting protocol for Modbus

Supporting protocol for SERCOS

Type of converter

U converter

Number of HW-interfaces parallel

0

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for ASI

Number of interfaces PROFINET

0

With PC connection

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Supporting protocol for other bus systems

Number of phases input

3

Integrated breaking resistance

Nominal output current I2N

145A

Max. output at quadratic load at rated output voltage

75kW

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Max. output voltage

480V

Max. output frequency

500Hz

Application in industrial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Max. output at linear load at rated output voltage

75kW

Supporting protocol for PROFINET CBA