Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth375mm
Width345mm
Supporting protocol for LONNo
Number of analogue inputs3
Height1250mm
Number of analogue outputs2
With control elementYes
Number of digital inputs8
Number of digital outputs1
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4853
Number of HW-interfaces USB0
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Number of HW-interfaces other0
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Mains voltage380 - 480V
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleYes
Mains frequency50/60 Hz
Supporting protocol for Data-HighwayNo
With PC connectionNo
Degree of protection (IP)IP55
Supporting protocol for SUCONETNo
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Max. output frequency500Hz
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Max. output at linear load at rated output voltage90kW
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Integrated breaking resistanceNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance5%
Type of converterU converter
Nominal output current I2N173A
Number of phases input3
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage90kW
Max. output voltage480V
Supporting protocol for PROFINET IOYes
Number of phases output3
Application in domestic- and commercial area permittedYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950D90N4 | ATV950 IP55 90KW 400v/480v

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

375mm

Width

345mm

Supporting protocol for LON

Number of analogue inputs

3

Height

1250mm

Number of analogue outputs

2

With control element

Number of digital inputs

8

Number of digital outputs

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

3

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for ASI

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Number of HW-interfaces other

0

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Mains frequency

50/60 Hz

Supporting protocol for Data-Highway

With PC connection

Degree of protection (IP)

IP55

Supporting protocol for SUCONET

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Max. output frequency

500Hz

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Max. output at linear load at rated output voltage

90kW

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Integrated breaking resistance

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

5%

Type of converter

U converter

Nominal output current I2N

173A

Number of phases input

3

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

90kW

Max. output voltage

480V

Supporting protocol for PROFINET IO

Number of phases output

3

Application in domestic- and commercial area permitted