Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height678mm
Depth300mm
Number of digital inputs8
Width264mm
With control elementYes
Number of digital outputs1
Number of analogue inputs3
Supporting protocol for LONNo
Number of analogue outputs2
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Number of HW-interfaces RS-4853
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Supporting protocol for PROFIBUSYes
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Degree of protection (IP)IP55
Supporting protocol for Data-HighwayNo
With PC connectionNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Supporting protocol for CANYes
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380 - 480V
Mains frequency50/60 Hz
Supporting protocol for PROFINET IOYes
Max. output at quadratic load at rated output voltage3kW
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance5%
Application in industrial area permittedYes
Max. output at linear load at rated output voltage3kW
Supporting protocol for Foundation FieldbusNo
Number of phases input3
Relative symmetric net voltage tolerance10%
Type of converterU converter
Number of interfaces PROFINET0
Max. output voltage480V
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Integrated breaking resistanceNo
Supporting protocol for SafetyBUS pNo
4-quadrant operation possibleYes
Nominal output current I2N7.2A
Number of phases output3
Max. output frequency500Hz
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950U30N4E | ATV950 IP55 3KW 400v/480v s Sklopkom

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

678mm

Depth

300mm

Number of digital inputs

8

Width

264mm

With control element

Number of digital outputs

1

Number of analogue inputs

3

Supporting protocol for LON

Number of analogue outputs

2

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

3

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for KNX

Degree of protection (IP)

IP55

Supporting protocol for Data-Highway

With PC connection

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for CAN

Supporting protocol for INTERBUS-Safety

Mains voltage

380 .. 480V

Mains frequency

50/60 Hz

Supporting protocol for PROFINET IO

Max. output at quadratic load at rated output voltage

3kW

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

5%

Application in industrial area permitted

Max. output at linear load at rated output voltage

3kW

Supporting protocol for Foundation Fieldbus

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Type of converter

U converter

Number of interfaces PROFINET

0

Max. output voltage

480V

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Integrated breaking resistance

Supporting protocol for SafetyBUS p

4-quadrant operation possible

Nominal output current I2N

7.2A

Number of phases output

3

Max. output frequency

500Hz

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.