Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth330mm
With control elementYes
Number of digital inputs8
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPNo
Number of analogue outputs2
With optical interfaceNo
Height678mm
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4853
Number of digital outputs1
Number of HW-interfaces other0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Number of analogue inputs3
Width264mm
Supporting protocol for CANYes
Type of converterU converter
Number of interfaces PROFINET0
Supporting protocol for ASINo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Mains voltage380 - 480V
Supporting protocol for SERCOSNo
4-quadrant operation possibleYes
Integrated breaking resistanceNo
Degree of protection (IP)IP55
With PC connectionNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Number of phases input3
Application in industrial area permittedYes
Supporting protocol for PROFIBUSYes
Number of phases output3
Application in domestic- and commercial area permittedYes
Max. output frequency500Hz
Max. output voltage480V
Max. output at quadratic load at rated output voltage7.5kW
Supporting protocol for PROFIsafeNo
Relative symmetric net frequency tolerance5%
Supporting protocol for BACnetNo
Max. output at linear load at rated output voltage7.5kW
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Nominal output current I2N16.5A
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV950U75N4E | ATV950 IP55 7,5KW 400v/480v s Sklopkom

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

330mm

With control element

Number of digital inputs

8

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of analogue outputs

2

With optical interface

Height

678mm

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

3

Number of digital outputs

1

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Number of analogue inputs

3

Width

264mm

Supporting protocol for CAN

Type of converter

U converter

Number of interfaces PROFINET

0

Supporting protocol for ASI

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Mains voltage

380 .. 480V

Supporting protocol for SERCOS

4-quadrant operation possible

Integrated breaking resistance

Degree of protection (IP)

IP55

With PC connection

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Number of phases input

3

Application in industrial area permitted

Supporting protocol for PROFIBUS

Number of phases output

3

Application in domestic- and commercial area permitted

Max. output frequency

500Hz

Max. output voltage

480V

Max. output at quadratic load at rated output voltage

7.5kW

Supporting protocol for PROFIsafe

Relative symmetric net frequency tolerance

5%

Supporting protocol for BACnet

Max. output at linear load at rated output voltage

7.5kW

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Nominal output current I2N

16.5A

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.