  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type of supply voltageDC
Supply voltage DC24 - 24V
Number of relay outputs0
Max. number of time switches0
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet4
Processing time (1K, binary operation)0.025ms
Number of HW-interfaces USB1
Number of HW-interfaces Wireless0
ModelModular
Number of HW-interfaces RS-2320
Number of interfaces PROFINET0
Number of HW-interfaces RS-4850
Number of analogue outputs0
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
Number of analogue inputs0
Supporting protocol for CANNo
Number of digital outputs0
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Number of digital inputs0
Supporting protocol for ASIYes
Supporting protocol for ModbusNo
With optical interfaceNo
Supporting protocol for KNXNo
Number of HW-interfaces parallel0
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Long-Term Evolution (LTE)No
Supporting protocol for Foundation FieldbusNo
IO link masterYes
With displayNo
Type of memoryNVRAM
Memory size16384kByte
Additional program memory possibleYes
RedundancyYes
Rail mounting possibleNo
Rack-assembly possibleYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Suitable for safety functionsYes
SIL according to IEC 61508None
System accessoryNo
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G
Width130.3mm
Height134.6mm
Depth64.6mm
Explosion safety category for dustATEX dust-ex-protection, Cat. 3D
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for DNP3No
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Supporting protocol for PROFIsafeNo
Supporting protocol for IEC 60870No
Supporting protocol for IEC 61850 EthernetNo
Radio standard GSMNo
Radio standard GPRSNo
Radio standard UMTSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BMEH584040

Main Product Image

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type of supply voltage

DC

Supply voltage DC

24 .. 24V

Number of relay outputs

0

Max. number of time switches

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

4

Processing time (1K, binary operation)

0.025ms

Number of HW-interfaces USB

1

Number of HW-interfaces Wireless

0

Model

Modular

Number of HW-interfaces RS-232

0

Number of interfaces PROFINET

0

Number of HW-interfaces RS-485

0

Number of analogue outputs

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Number of analogue inputs

0

Supporting protocol for CAN

Number of digital outputs

0

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Number of digital inputs

0

Supporting protocol for ASI

Supporting protocol for Modbus

With optical interface

Supporting protocol for KNX

Number of HW-interfaces parallel

0

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Long-Term Evolution (LTE)

Supporting protocol for Foundation Fieldbus

IO link master

With display

Type of memory

NVRAM

Memory size

16384kByte

Additional program memory possible

Redundancy

Rail mounting possible

Rack-assembly possible

Wall mounting/direct mounting

Front built-in possible

Suitable for safety functions

SIL according to IEC 61508

None

System accessory

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ia)

Appendant operation agent (Ex ib)

Explosion safety category for gas

ATEX gas-ex-protection, Cat. 3G

Width

130.3mm

Height

134.6mm

Depth

64.6mm

Explosion safety category for dust

ATEX dust-ex-protection, Cat. 3D

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for DNP3

Radio standard Bluetooth

Radio standard Wi-Fi 802.11

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Supporting protocol for IEC 60870

Supporting protocol for IEC 61850 Ethernet

Radio standard GSM

Radio standard GPRS

Radio standard UMTS