Technical specifications

Width64.6mm
Height134.6mm
With displayYes
Depth130.3mm
Suitable for safety functionsYes
Number of digital inputs2048
ModelModular
Number of digital outputs2048
Processing time (1K, binary operation)0.1ms
Memory size8000kByte
Number of HW-interfaces industrial Ethernet3
Supporting protocol for LONNo
Number of analogue outputs512
Number of HW-interfaces other32
Max. number of addressable analogue I/O-ports512
Voltage type of supply voltageDC
Number of HW-interfaces USB1
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of analogue inputs512
Max. number of addressable digital I/O-ports2048
Supporting protocol for TCP/IPYes
Supporting protocol for ASIYes
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Type of memoryRAM
Additional program memory possibleYes
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G
Supporting protocol for DeviceNetNo
Radio standard BluetoothNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Category according to EN 954-11
Radio standard Wi-Fi 802.11No
Appendant operation agent (Ex ib)No
Rack-assembly possibleYes
RedundancyNo
Number of interfaces PROFINET0
Wall mounting/direct mountingNo
Number of HW-interfaces Wireless0
Number of relay outputs0
Front built-in possibleNo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Rail mounting possibleNo
Explosion safety category for dustATEX dust-ex-protection, Cat. 3D
System accessoryNo
IO link masterNo
Appendant operation agent (Ex ia)No
Max. number of time switches0
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Performance level according to EN ISO 13849-1None
SIL according to IEC 61508None
Supply voltage DC24 - 24V
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Radio standard UMTSNo
Radio standard GPRSNo
Supporting protocol for SafetyBUS pNo
Supply voltage AC 60 Hz- - undefinedV
Supporting protocol for PROFIsafeNo
Radio standard GSMNo
Supporting protocol for Foundation FieldbusNo
Supply voltage AC 50 Hz- - undefinedV
Supporting protocol for AS-Interface Safety at WorkNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BMEP582020H | M580 hardened processor Level 2 for DIO

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

64.6mm

Height

134.6mm

With display

Depth

130.3mm

Suitable for safety functions

Number of digital inputs

2048

Model

Modular

Number of digital outputs

2048

Processing time (1K, binary operation)

0.1ms

Memory size

8000kByte

Number of HW-interfaces industrial Ethernet

3

Supporting protocol for LON

Number of analogue outputs

512

Number of HW-interfaces other

32

Max. number of addressable analogue I/O-ports

512

Voltage type of supply voltage

DC

Number of HW-interfaces USB

1

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces serial TTY

0

Number of analogue inputs

512

Max. number of addressable digital I/O-ports

2048

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for KNX

Type of memory

RAM

Additional program memory possible

Explosion safety category for gas

ATEX gas-ex-protection, Cat. 3G

Supporting protocol for DeviceNet

Radio standard Bluetooth

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Category according to EN 954-1

1

Radio standard Wi-Fi 802.11

Appendant operation agent (Ex ib)

Rack-assembly possible

Redundancy

Number of interfaces PROFINET

0

Wall mounting/direct mounting

Number of HW-interfaces Wireless

0

Number of relay outputs

0

Front built-in possible

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Rail mounting possible

Explosion safety category for dust

ATEX dust-ex-protection, Cat. 3D

System accessory

IO link master

Appendant operation agent (Ex ia)

Max. number of time switches

0

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Performance level according to EN ISO 13849-1

None

SIL according to IEC 61508

None

Supply voltage DC

24 .. 24V

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Radio standard UMTS

Radio standard GPRS

Supporting protocol for SafetyBUS p

Supply voltage AC 60 Hz

- .. undefinedV

Supporting protocol for PROFIsafe

Radio standard GSM

Supporting protocol for Foundation Fieldbus

Supply voltage AC 50 Hz

- .. undefinedV

Supporting protocol for AS-Interface Safety at Work

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.