Aleta.hr

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

ModelModular
Number of digital inputs4096
Height134.6mm
With displayYes
Depth130.3mm
Width64.6mm
Suitable for safety functionsNo
Number of analogue outputs1024
Voltage type of supply voltageAC/DC
Number of digital outputs4096
Number of HW-interfaces RS-2320
Type of memoryNVRAM
Number of HW-interfaces RS-4850
Number of analogue inputs1024
Number of HW-interfaces RS-4220
Processing time (1K, binary operation)0.01ms
Memory size18000kByte
Number of HW-interfaces USB1
Supporting protocol for LONNo
With optical interfaceNo
Number of HW-interfaces industrial Ethernet3
Number of HW-interfaces parallel0
Number of HW-interfaces other64
Supporting protocol for CANNo
Supporting protocol for ASIYes
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Additional program memory possibleYes
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Rail mounting possibleNo
RedundancyNo
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G
Explosion safety category for dustATEX dust-ex-protection, Cat. 3D
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Appendant operation agent (Ex ib)No
System accessoryNo
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Front built-in possibleNo
Supporting protocol for INTERBUS-SafetyNo
Rack-assembly possibleYes
Number of HW-interfaces Wireless0
Number of interfaces PROFINET0
Max. number of time switches0
Radio standard BluetoothNo
Number of relay outputs0
Radio standard Wi-Fi 802.11No
Wall mounting/direct mountingNo
IO link masterNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Performance level according to EN ISO 13849-1None
Radio standard GPRSNo
Supporting protocol for PROFIsafeNo
Supply voltage AC 60 Hz0 - 0V
Supply voltage DC24 - 24V
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Radio standard GSMNo
Radio standard UMTSNo
SIL according to IEC 61508None
Supporting protocol for DNP3No
Long-Term Evolution (LTE)No
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for IEC 60870No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BMEP584040 | M580 processor level 4 for D and R IOs

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Model

Modular

Number of digital inputs

4096

Height

134.6mm

With display

Depth

130.3mm

Width

64.6mm

Suitable for safety functions

Number of analogue outputs

1024

Voltage type of supply voltage

AC/DC

Number of digital outputs

4096

Number of HW-interfaces RS-232

0

Type of memory

NVRAM

Number of HW-interfaces RS-485

0

Number of analogue inputs

1024

Number of HW-interfaces RS-422

0

Processing time (1K, binary operation)

0.01ms

Memory size

18000kByte

Number of HW-interfaces USB

1

Supporting protocol for LON

With optical interface

Number of HW-interfaces industrial Ethernet

3

Number of HW-interfaces parallel

0

Number of HW-interfaces other

64

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Additional program memory possible

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for Modbus

Rail mounting possible

Redundancy

Explosion safety category for gas

ATEX gas-ex-protection, Cat. 3G

Explosion safety category for dust

ATEX dust-ex-protection, Cat. 3D

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Appendant operation agent (Ex ib)

System accessory

Appendant operation agent (Ex ia)

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Front built-in possible

Supporting protocol for INTERBUS-Safety

Rack-assembly possible

Number of HW-interfaces Wireless

0

Number of interfaces PROFINET

0

Max. number of time switches

0

Radio standard Bluetooth

Number of relay outputs

0

Radio standard Wi-Fi 802.11

Wall mounting/direct mounting

IO link master

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Performance level according to EN ISO 13849-1

None

Radio standard GPRS

Supporting protocol for PROFIsafe

Supply voltage AC 60 Hz

0 .. 0V

Supply voltage DC

24 .. 24V

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Radio standard GSM

Radio standard UMTS

SIL according to IEC 61508

None

Supporting protocol for DNP3

Long-Term Evolution (LTE)

Supporting protocol for IEC 61850 Ethernet

Supporting protocol for IEC 60870

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.