Details
- •Programmable logic controllers PLC
- •PLC CPU-module
- •1 KOM
- •SCHNEIDER
Technical specifications
BMEP585040C | C M580 Processor Level 5 for R IO

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Height
0mm
Width
0mm
Depth
0mm
Model
Modular
With display
Number of digital inputs
5120
Suitable for safety functions
Number of digital outputs
5120
Memory size
24576kByte
Type of memory
RAM
Voltage type of supply voltage
DC
Max. number of addressable analogue I/O-ports
1280
Number of HW-interfaces RS-422
0
Number of analogue inputs
1280
Supporting protocol for LON
Processing time (1K, binary operation)
0.025ms
Number of HW-interfaces RS-485
0
Number of analogue outputs
1280
Number of HW-interfaces industrial Ethernet
3
Max. number of addressable digital I/O-ports
5120
Number of HW-interfaces RS-232
0
Supporting protocol for ASI
Number of HW-interfaces other
0
With optical interface
Additional program memory possible
Supporting protocol for TCP/IP
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
1
Number of HW-interfaces serial TTY
0
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Rail mounting possible
Explosion safety category for dust
ATEX dust-ex-protection, Cat. 3D
Supporting protocol for KNX
Supporting protocol for other bus systems
Supporting protocol for CAN
System accessory
Appendant operation agent (Ex ia)
Redundancy
Supporting protocol for PROFIBUS
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Appendant operation agent (Ex ib)
Number of HW-interfaces Wireless
0
Supporting protocol for INTERBUS-Safety
Number of interfaces PROFINET
0
Wall mounting/direct mounting
Front built-in possible
Radio standard Bluetooth
Supporting protocol for SERCOS
Rack-assembly possible
Category according to EN 954-1
1
IO link master
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Number of relay outputs
0
Supporting protocol for PROFINET CBA
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Max. number of time switches
0
Radio standard Wi-Fi 802.11
Performance level according to EN ISO 13849-1
None
Supply voltage AC 60 Hz
- .. undefinedV
Radio standard GSM
Radio standard GPRS
Supporting protocol for PROFINET IO
Supply voltage AC 50 Hz
- .. undefinedV
Supply voltage DC
24 .. 24V
Supporting protocol for SafetyBUS p
Radio standard UMTS
SIL according to IEC 61508
None