Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu50A
Type of control elementToggle
Degree of protection (IP)IP40
Motor drive integratedNo
Overload release current setting35 - 50A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz16kA
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range short-term delayed short-circuit release- - -A
Adjustment range undelayed short-circuit release600 - 600A
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
With switched-off indicatorYes
Number of poles3
Number of auxiliary contacts as normally closed contact0
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426104

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

50A

Type of control element

Toggle

Degree of protection (IP)

IP40

Motor drive integrated

Overload release current setting

35 .. 50A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

16kA

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

Adjustment range undelayed short-circuit release

600 .. 600A

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

With under voltage release

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.