  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu80A
Overload release current setting56 - 80A
Type of electrical connection of main circuitFrame clamp
Motor drive optionalNo
Motor drive integratedNo
Rated voltage690 - 690V
Device constructionComplete device in housing
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release1000 - 1000A
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
With under voltage releaseNo
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz16kA
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426106

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

80A

Overload release current setting

56 .. 80A

Type of electrical connection of main circuit

Frame clamp

Motor drive optional

Motor drive integrated

Rated voltage

690 .. 690V

Device construction

Complete device in housing

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1000 .. 1000A

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

With under voltage release

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

16kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection