Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Number of poles4
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu50A
Overload release current setting35 - 50A
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Motor drive integratedNo
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release600 - 600A
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz16kA
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426114

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

4

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

50A

Overload release current setting

35 .. 50A

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

600 .. 600A

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

16kA

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

With switched-off indicator