Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu50A
Degree of protection (IP)IP40
Overload release current setting35 - 50A
Number of poles4
Rated voltage690 - 690V
With switched-off indicatorYes
Motor drive optionalNo
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release600 - 600A
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV426264

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

50A

Degree of protection (IP)

IP40

Overload release current setting

35 .. 50A

Number of poles

4

Rated voltage

690 .. 690V

With switched-off indicator

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

600 .. 600A

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

With under voltage release

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.