  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Type of control elementToggle
Number of poles3
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu80A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Overload release current setting56 - 80A
Device constructionComplete device in housing
Type of electrical connection of main circuitFrame clamp
Motor drive optionalNo
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release1000 - 1000A
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With under voltage releaseNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426406

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Type of control element

Toggle

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

80A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Overload release current setting

56 .. 80A

Device construction

Complete device in housing

Type of electrical connection of main circuit

Frame clamp

Motor drive optional

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1000 .. 1000A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Integrated earth fault protection