  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of poles3
Rated permanent current Iu80A
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Overload release current setting56 - 80A
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP40
Type of control elementToggle
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorYes
Motor drive integratedNo
With under voltage releaseNo
Complete device with protection unitYes
Adjustment range undelayed short-circuit release1000 - 1000A
Integrated earth fault protectionNo
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426456

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of poles

3

Rated permanent current Iu

80A

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Overload release current setting

56 .. 80A

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP40

Type of control element

Toggle

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Motor drive integrated

With under voltage release

Complete device with protection unit

Adjustment range undelayed short-circuit release

1000 .. 1000A

Integrated earth fault protection

Motor drive optional

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional