Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Degree of protection (IP)IP40
Overload release current setting28 - 40A
Type of control elementToggle
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Motor drive optionalNo
With switched-off indicatorYes
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release600 - 600A
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu40A
Number of poles4
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV426463

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP40

Overload release current setting

28 .. 40A

Type of control element

Toggle

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Motor drive optional

With switched-off indicator

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

600 .. 600A

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With under voltage release

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

40A

Number of poles

4

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.