Technical specifications

Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Overload release current setting112 - 160A
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1250 - 1250A
Suitable for DIN rail (top hat rail) mountingYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With under voltage releaseNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426509

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Overload release current setting

112 .. 160A

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1250 .. 1250A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Integrated earth fault protection