Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Degree of protection (IP)IP40
Overload release current setting11.2 - 16A
Position of connection for main current circuitFront side
With switched-off indicatorYes
Type of electrical connection of main circuitScrew connection
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release500 - 500A
Complete device with protection unitYes
Integrated earth fault protectionNo
With under voltage releaseNo
Motor drive optionalNo
Adjustment range short-term delayed short-circuit release- - -A
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingYes
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu16A
Number of poles4
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV426510

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Degree of protection (IP)

IP40

Overload release current setting

11.2 .. 16A

Position of connection for main current circuit

Front side

With switched-off indicator

Type of electrical connection of main circuit

Screw connection

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

500 .. 500A

Complete device with protection unit

Integrated earth fault protection

With under voltage release

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

16A

Number of poles

4

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA