  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Position of connection for main current circuitFront side
Overload release current setting70 - 100A
Number of auxiliary contacts as normally closed contact0
Type of control elementToggle
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release- - -A
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP40
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release1250 - 1250A
Integrated earth fault protectionNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Motor drive optionalNo
Rated permanent current Iu100A
Number of poles4
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV426567

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Position of connection for main current circuit

Front side

Overload release current setting

70 .. 100A

Number of auxiliary contacts as normally closed contact

0

Type of control element

Toggle

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP40

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1250 .. 1250A

Integrated earth fault protection

With under voltage release

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive optional

Rated permanent current Iu

100A

Number of poles

4

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA