Technical specifications

Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu50A
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Rated operation power at AC-3, 400 V-kW
Degree of protection (IP), front sideIP40
Suitable for floor mountingYes
Suitable for intermediate mountingYes
Suitable for distribution board installationYes
Max. rated operation voltage Ue AC690V
Conditioned rated short-circuit current Iq-kA
Rated short-time withstand current lcw0.9kA
Rated operating voltage690 - 690V
Rated operation power at AC-23, 400 V-kW
Colour control elementBlack
Version as emergency stop installationNo
Version as safety switchNo
InterlockableNo
Version as reversing switchNo
Suitable for front mounting 4-holeYes
Version as maintenance-/service switchYes
Switching power at 400 V-kW
Voltage release optionalYes
Number of switches1
Version as main switchYes
Suitable for front mounting centreNo
Rated permanent current at AC-21, 400 V50A
Rated permanent current at AC-23, 400 V50A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426600

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

50A

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Rated operation power at AC-3, 400 V

-kW

Degree of protection (IP), front side

IP40

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Max. rated operation voltage Ue AC

690V

Conditioned rated short-circuit current Iq

-kA

Rated short-time withstand current lcw

0.9kA

Rated operating voltage

690 .. 690V

Rated operation power at AC-23, 400 V

-kW

Colour control element

Black

Version as emergency stop installation

Version as safety switch

Interlockable

Version as reversing switch

Suitable for front mounting 4-hole

Version as maintenance-/service switch

Switching power at 400 V

-kW

Voltage release optional

Number of switches

1

Version as main switch

Suitable for front mounting centre

Rated permanent current at AC-21, 400 V

50A

Rated permanent current at AC-23, 400 V

50A