Technical specifications

Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Overload release current setting63 - 160A
Rated voltage440 - 440V
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release2000 - 2000A
Suitable for DIN rail (top hat rail) mountingYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release94.5 - 1600A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Integrated earth fault protectionYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426783

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Overload release current setting

63 .. 160A

Rated voltage

440 .. 440V

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

2000 .. 2000A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

94.5 .. 1600A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

With under voltage release