Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Position of connection for main current circuitFront side
Rated voltage690 - 690V
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz200kA
Type of electrical connection of main circuitScrew connection
Overload release current setting28 - 40A
Degree of protection (IP)IP40
Rated permanent current Iu40A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release500 - 500A
Number of poles3
Adjustment range short-term delayed short-circuit release- - -A
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Integrated earth fault protectionNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV433200

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Position of connection for main current circuit

Front side

Rated voltage

690 .. 690V

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

200kA

Type of electrical connection of main circuit

Screw connection

Overload release current setting

28 .. 40A

Degree of protection (IP)

IP40

Rated permanent current Iu

40A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

500 .. 500A

Number of poles

3

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Motor drive optional

Device construction

Built-in device fixed built-in technique

With under voltage release

Integrated earth fault protection

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.