Aleta.hr
Main Product Image

LXM28AU04M3X

Code: 1758327

ManufacturerRAZNO
Catalog numberLXM28AU04M3X
Type
EAN code3606480711787

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

220 - 220V

Number of phases output

3

Max. output frequency

16Hz

Max. output voltage

240V

Number of digital outputs

2

Relative symmetric net voltage tolerance

10%

Number of analogue inputs

3

Application in industrial area permitted

Yes

Number of digital inputs

6

Number of analogue outputs

1

Supporting protocol for CAN

Yes

Supporting protocol for TCP/IP

No

Supporting protocol for ASI

No

Max. output at quadratic load at rated output voltage

0.4kW

Supporting protocol for Modbus

Yes

Supporting protocol for SUCONET

No

Max. output at linear load at rated output voltage

0.4kW

Relative symmetric net frequency tolerance

5%

Application in domestic- and commercial area permitted

Yes

Supporting protocol for KNX

No

Supporting protocol for PROFIBUS

No

Nominal output current I2N

2.6A

Supporting protocol for INTERBUS

No

Supporting protocol for LON

No

Number of phases input

1

Supporting protocol for DeviceNet

No

Supporting protocol for Data-Highway

No

With control element

Yes

Mains frequency

50/60 Hz

With optical interface

No

Integrated breaking resistance

Yes

4-quadrant operation possible

No

Type of converter

Direct converter

With PC connection

No

Degree of protection (IP)

IP20

Width

55mm

Height

150mm

Depth

146mm

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for BACnet

No

Supporting protocol for other bus systems

No

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of interfaces PROFINET

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LXM28AU04M3X

Main Product Image

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

220 .. 220V

Number of phases output

3

Max. output frequency

16Hz

Max. output voltage

240V

Number of digital outputs

2

Relative symmetric net voltage tolerance

10%

Number of analogue inputs

3

Application in industrial area permitted

Number of digital inputs

6

Number of analogue outputs

1

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for ASI

Max. output at quadratic load at rated output voltage

0.4kW

Supporting protocol for Modbus

Supporting protocol for SUCONET

Max. output at linear load at rated output voltage

0.4kW

Relative symmetric net frequency tolerance

5%

Application in domestic- and commercial area permitted

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Nominal output current I2N

2.6A

Supporting protocol for INTERBUS

Supporting protocol for LON

Number of phases input

1

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

With control element

Mains frequency

50/60 Hz

With optical interface

Integrated breaking resistance

4-quadrant operation possible

Type of converter

Direct converter

With PC connection

Degree of protection (IP)

IP20

Width

55mm

Height

150mm

Depth

146mm

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for other bus systems

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of interfaces PROFINET

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.