Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height270mm
Depth237mm
Width48mm
Number of digital inputs6
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs1
With control elementNo
Supporting protocol for LONNo
Number of analogue inputs3
Number of HW-interfaces RS-4850
Number of digital outputs2
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces other0
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
With PC connectionNo
Supporting protocol for SUCONETNo
Degree of protection (IP)Other
Number of interfaces PROFINET0
Mains voltage115 - 230V
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Integrated breaking resistanceNo
Number of phases output1
Type of converterOther
Number of phases input1
Max. output at linear load at rated output voltage1kW
Max. output frequency8Hz
Application in domestic- and commercial area permittedNo
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance5%
Max. output at quadratic load at rated output voltage1kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Nominal output current I2N6A
Supporting protocol for BACnetNo
Supporting protocol for Foundation FieldbusNo
Max. output voltage230V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LXM32CD18M2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

270mm

Depth

237mm

Width

48mm

Number of digital inputs

6

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

1

With control element

Supporting protocol for LON

Number of analogue inputs

3

Number of HW-interfaces RS-485

0

Number of digital outputs

2

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for ASI

Supporting protocol for Data-Highway

Number of HW-interfaces other

0

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

With PC connection

Supporting protocol for SUCONET

Degree of protection (IP)

Other

Number of interfaces PROFINET

0

Mains voltage

115 .. 230V

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Integrated breaking resistance

Number of phases output

1

Type of converter

Other

Number of phases input

1

Max. output at linear load at rated output voltage

1kW

Max. output frequency

8Hz

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

5%

Max. output at quadratic load at rated output voltage

1kW

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Nominal output current I2N

6A

Supporting protocol for BACnet

Supporting protocol for Foundation Fieldbus

Max. output voltage

230V